DRB 16 012
DRB 16 012
Designed for general Purpose Aircraft Wiring Applications.
Multicores DRA
- Rif. Lynxeo : EN 2267-009B 012P (DRB 16)
- Paese rif. : 10121194
Descrizione
Descrizione
Norme
-
ProductEN 2267-009
-
TestprEN 3475
DESIGN CONSTRUCTION
CORES
2, 3 or 4 cores EN2267-009A
IDENTIFICATION
| Colours of cores | : See table in this datasheet |
|
Colours of marking |
: White for red and green core, green for blue and yellow cores |
| Marking | : EN DRA ** FR F ++ |
| DRA = short designation | |
| ** = AWG | |
| FR = Country of origin (FR = France) | |
| F = Manufacturer (F = Lynxeo) | |
| ++ = Year of production (i.e. 14 = 2014) |
ELECTRICAL AND HIGH FREQUENCY PERFORMANCES
Voltage rating : 600 Volts RMS at sea level,
Usual Aerospace application are using 115 volts (Phase to neutral)
And 200 Volts (Phase to phase) 400 Hz AC or 29 Volts DC.
Maximum operating frequency: 2000Hz
Caratteristiche
Caratteristiche
Caratteristiche costruttive
Caratteristiche costruttive
Colore
P
Tipo di conduttore
-
Identificazione delle anime
Rosso, blu
Numero di conduttori
-
Size code
-
Caratteristiche dimensionali
Caratteristiche dimensionali
Diametro esterno max
3,84 mm
Diametro esterno nominale del cavo
3,66 mm
Numero di anime
2
Peso Massimo
30,1 g/m
Nominal weight
28,66 g/m
Caratteristiche elettriche
Caratteristiche elettriche
Frequenza massima di funzionamento
0,002 MHz
Maximum DC resistance at 20°C
14,9 Ohm/100m
Tensione operativa
600 V
Caratteristiche d'utilizzo
Caratteristiche d'utilizzo
Ritardante la fiamma
FAR/JAR part 25 sec 25.869 (a)(4) Appendix F part 1 (3)
Resistenza all'olio
Very good resistance to aircraft fluids
Arc tracking resistant
Sì
Conforme RoHS (2002/95/CE)
Sì
Temperatura Operativa
-55 ... 260 °C